Back to: Home > Our Products > 2U Redundant > TC-R2U > TC-400R2U
   TC-400R2U
Model : TC-400R2U   Power : 400W
> AC Input:

- VOLTAGE: 100~240V(Active PFC/Full Range)
- FREQUENCY: 47~63Hz
- POWER FACTOR CORRECTION: 0.95
- INPUT CURRENT: 8A/4A For 115/230VAC
- INRUSH CURRENT: 60A/80A MAX FOR 115/230

   DC Output
OUTPUT
VOLTAGE
OUTPUT CURRENT
REGULATION
OUTPUT
MIN(A)
MAX(A)
LOAD
LINE
RIPPLE & NOISE
MAX.[P-P]
+5V
3
25
±5%
±1%
50mV
+12V
2
28
±5%
±1%
120mV
-5V
0.1
0.5
±10%
±1%
150mV
-12V
0.1
0.8
±10%
±1%
150mV
+3.3V
1
25
±5%
±1%
50mV
+5VSB
0.1
2
±5%
±1%
50mV
The combined output power +5V&+3.3V shall not exceed 40A.
The total power shall not exceed 400W.


   Features

> TEMPERATURE RANGE:Operation 0℃~50℃
> HOLD UP TIME:16ms at maximum load & normal input voltage
> EFFICIENCY:73% TYPICAL(Normal Line)
> ATX 12V / EPS 12V
> POWER GOOD SIGNAL:Should be asserted high to indicate that+5VDC and +3.3VDC
   output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION:The power supply shall shout down output power exceeds 130% to 160%
> OVER VOLTAGE PROTECTION:+5V, +3.3V and +12V DC outputs set at 110%-130%
> SHORT CIRCUIT PROTECTION:A short circuit placed between the DC return and
   the output shall cause no damage and the power supply shall shutdown.
> EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
> Meet EN-61000-3-2 CLASS D ( Active PFC )
> AGENCY APPROVALS:UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
> MTBF OF POWER SUPPLY ELECTRONNIS:100,000 hours at 25℃. LIFE EXPCTANCY OF FAN 40,000 hours at 40℃
> COOLING:By forced air 1x40mm Fan (Each module)
> DIMENSION:D280 X W101 X H84mm

   Download

> Product Flyer:

 

   Connectors

24 Pin
P4 MB
Peripheral
FDD
8-Pin
SATA
X 1
X 1
X 5
X 1
X 1
X2