Back to: Home > Our Products > N+1 Redundant > TC-RVN2 > TC-600RVN2
Model : TC-600RVN2  Power : 600W
> AC Input:

- VOLTAGE: 90~264VAC Full Range
- FREQUENCY: 50/60Hz.
- INPUT CURRENT: 8A for 115V AC, 4A for 230VAC.
- INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC


   DC Output
Each of the 1+1 redundant power supply module shall be capable of supplying the output currents of as below subject to the listed conditions and a total output power of 600watts. Due to the active current share, the actual maximum steady state current from each output shall be about half of the maximum current specified.

Output Voltage +5V DC +12V DC +3.3V DC -12V DC +5VSB 
Output Current(Max) 32A 42A 25A 1A 3A
Output Current(Min.) 1A 3A 1A 0A 0.1A
Ripple/Noise Max.(P-P): 50mv 70mv 50mv 70mv 50mV
Line Regulation: ±1﹪ ±1﹪ ±1﹪ ±1﹪ ±1﹪
Load Regulation: ±5﹪ ±5﹪ ±5﹪ ±5﹪ ±5﹪

1.Total Max output of +5V AND +3.3V not exceed 200W
2.Power module Total output power not exceed 600W forTC-600RVN2
3.Noise bandwidth is from DC to 20MHz.


> DIMENSION:D300 X W101 X H84mm / D11.81 x W3.98 x H3.3 (inches)
> TEMPERATURE RANGE: Operation 0℃~50℃, Non Operating: -20℃to +70℃
> Output voltage hold up time: Upon loss of an ac input at any input voltage between 115/230V, the output voltages of the system shall remain in regulation for at least 16 ms at full output loads.
> EFFICIENCY: 76% Typical at full load
> ATX 12V / EPS 12V
> Power good signal: The system shall have an active high TTL compatible signal capable of sinking 1mA and sourcing 100uA. The signal shall become active within 100 to 500 ms from the instant +5V output reaches a steady state level within the specified regulation limits. It shall become inactive at least 1 ms before +5V drops to below the lower regulation limit.
> OVER POWER PROTECTION: OVER 110% ~ 150% of rated load Shut down latch off
> OVER VOLTAGE PROTECTION: Standard on +5.0V output, set at 6.9VDC ±0.75VDC
> SHORT CIRCUIT PROTECTION: All output equipped with short circuit.(Shut down o/p voltage, re-power on to recover).
> EMI/RFI standards: FCC part 15, class A, EN55022 CISPR22 Class A
> AGENCY APPROVALS: UL/cUL60950-1, TUV EN60950-1, CB Certification, CCC
> Mean Time Between Failure(MTBF): Using MIL - HDBK -217F the calculated MTBF>100,000 hours at 25℃.


24 Pin
X 1
X 2
X 18
X 2
X 1